以淮安地震台数字测震系统设备为例,作者根据多年台站观测工作经验,提出更加适用的测震系统观测方案,结合观测中遇到的各类故障,总结归类出故障的现象、排查方法、应对措施和注意事项。
Taking the digital seismic system in Huaian Seismic Station for example,a suitable countermeasure is put forward of the seismic obseration system Based on years of working experience, combined with various types of faults encountered in the observation, the classification of the phenomenon of failure, the investigation method, and the response measures and precautions are summarized.