工业锅炉蒸汽湿度低于0.5%的简易水平流动汽水分离 被引量:1

Horizontal Flow Type Steam Water Separation for Cutting the Steam Moisture of Industrial Boilers Down to 0.5%
下载PDF
导出
摘要 提出的工业锅炉汽水重力分离由常用的上升流动分离、惯性分离,改为沿锅筒长度水平流动分离,不仅使蒸汽湿度低于0.5%(明显低于我国标准的限定值3%~4%),而且,无需复杂汽水分离设备;给出其应用情况与验证测试结果,并着重分析水平流动高效分离的机理。以上表明技术创新会带来显著效果。 Put forward that the steam water gravity separation with horizontal ilow along the length of drum instead of the common separation, such as rise flow separation , force of inertia separation, not only makes thc steam moisture below 0.5% (obviously lower than the standard limit of 3%- 4% ) , but also without complex separation e- quipment ;and introduces its application situation and proving test results, also specially effort to analysis the theory of steam moisture reduction.
作者 李之光 梁耀东 张仲敏 徐甫 张振 刘复田 LI Zhi-guang;LIANG Yao-dong;ZHANG Zhong-min;XU Fu;ZHANG Zheng;LIU Fu-tian(Beijing Shengchang Zhiguang Boiler Research Institute, Beijing 100195,China;Liaoning Shengchang Green Energy Boiler Co.,Yingkou 115000 , Liaoning , China;Shanghai Industrial Boiler Research Institute, Shanghai 201114 , China)
出处 《工业锅炉》 2017年第6期16-21,共6页 Industrial Boilers
关键词 汽水分离 水平流动汽水分离 降低蒸汽湿度 机理 steam water separation horizontal flow type steam water separation steam moisture reduction theory
  • 相关文献

参考文献2

二级参考文献10

  • 1李之光.蒸汽型水火管锅壳锅炉特点与改进措施[A].DZL新型水火管锅炉论文专集[c].2002.
  • 2李守恒,杨厉丹,等.电站锅炉汽水分离装置的原理与设计[M].北京:水利电力出版社,1988.
  • 3GB/T16508-1996.锅壳锅炉受压元件强度计算[S].[S].,..
  • 4李之光 蒋智翔.锅炉受压元件强度[M].北京:技术标准出版社,1980..
  • 5李之光,梁耀东,牛全正,等.工业锅炉现代设计与开发[M].北京:中国质检出版社,中国标准出版社,2011.
  • 6GB/T16508.3-2013锅壳锅炉设计与强度计算[S].
  • 7董芃,刘曼青,李之光.烟管锅炉拱形管板强度的研究[J].工业锅炉,1987(2):1-10.
  • 8李之光,王昌明,刘复田,沈希度,朱永根,黄建庭.新型水火管锅壳锅炉凸形管板的论述[J].工业锅炉,1997(3):9-14. 被引量:4
  • 9梁耀东,李之光,刘峰,徐甫,刘立波.冷凝燃气锅炉评价与热效率计算[J].工业锅炉,2015(4):36-41. 被引量:9
  • 10李之光,李志强,刘曼青,王铣庆,董芃.凸形管板的强度计算问题[J].工业锅炉,1992(3):5-14. 被引量:9