摘要 针对气体超声波流量计信号衰减严重、干扰较大的问题,设计了一种适用于气体超声波流量计的互易性收发电路,以消除零点漂移现象提高流量计的测量准确度。换能器配对实验和温度实验表明:互易性测量系统显著改善了流量计的零点漂移问题,并具有良好的测量稳定性。 The ultrasonic signal decays severely and can be easily affected by noise during the propagation in gas.Considering these factors,reciprocal electronic circuits for gas ultrasonic flow meter are designed. Two experiments are carried out to test the reciprocal circuits,including transducers paired experiment and temperature test. It is verified that the reciprocal circuits can improve the measurement accuracy and stability for gas ultrasonic flow meter.
出处 《传感器与微系统》 CSCD 2017年第12期112-113,117,共3页 Transducer and Microsystem Technologies
基金 国家自然科学基金资助项目(61671317 61101227) 天津市应用基础与前沿技术研究计划资助项目(13JCQNJC03300)
关键词 气体超声波流量计 互易电路 零点漂移 电路设计 gas ultrasonic flowmeter reciprocity circuit zero drift circuit design
  • 相关文献

参考文献2

二级参考文献24

  • 1Ishibashi Masahiro,Takamoto Masaki. Methods to calibrate a cri-tical nozzle and flowmeter using reference cri-tical nozzles [ J ]. Flow Measurement and Instrumentation,2000 (11) : 293 -303.
  • 2Edgar. Natural gas flow measurement in the 21st century [J]. Pipeline&Gas Journal,1999,26(7) :18 -21.
  • 3Lansing J.4-inch ultrasionic meter for custody transfer application[J]. Pipeline Gas Journal, 1999,226 ( 7 ) :34 -35.
  • 4Amy K, Roger G. Software-gated pulse-Doppler ultrasound for a DSP-based blood flowmeter[C]//2000 IEEE Intemtional Conference on Acoustics, Speech, and Signal Processing ,2000:3598 - 3601.
  • 5Drenthen J G, Boer G. The manufacturing of ultrasonic gas flow meter[ J ]. Flow measurements and Instrumentation, 2001 ( 12 ) : 89 -99.
  • 6Roosnek N. Novel digital signal processing techniques for ultrasonic gas flow measurements [ J ]. Flow Measurements and Instrumentation ,2000 ( 11 ) :89-99.
  • 7Takamoto M, Ishikawa H, Shimizu K, et al. New measurement method for very low liquid flow rates using ultrasound [ J ]. Flow Measurements and Instrumentation ,2001 ( 8 ) :267 -273.
  • 8Tewodros A. Design of an electromagnetic flowmeter for insulating liquids [ J ]. Measurement Science and Technology, 1999,10 ( 8 ) : 755 -758.
  • 9Zhang X Z. The 2D analysis for the virtual current distribution in an electromagnetic flow meter with a bubble at its different axis positions [ J ]. Measur Sci and Techn, 1998 (9) : 1 -5.
  • 10Michalski Andrzej. Dry calibration procedure of electromagnetic flowmeter for open channels [ J ]. IEEE Transactions on Instrumentation and Measurement,2000 (49) : 434 -438.

共引文献20

同被引文献42

引证文献6

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部