摘要
目前国内水电站多数主配压阀均存在不同程度的渗油问题,通过对深溪沟水电站主配压阀渗油实际情况进行分析,明确了渗油原因并采取有效处理方法,成功地排除了故障。
Oil leakage of the main distributing valve is a common problem in hydropower stations in China. The excessive oil leakage problem in the main distributing valve of the hydro-turbine governor in Shenxigou Hydropower Station is analyzed. The reason of this problem is determined and corresponding treatment measures are taken. After the treatment,the oil leakage problem is successfully solved.
出处
《水电与新能源》
2017年第12期58-60,共3页
Hydropower and New Energy
关键词
调速器
主配压阀
漏油
油质
分析
governor
main distributing valve
oil leakage
oil quality