某公司燃机扩建工程循环水系统冷端优化

Cold End Optimization of Circulating Water System in the Gas Turbine Expansion Project of a Company
下载PDF
导出
摘要 某公司扩建燃机工程,主机选用三菱机组,冷却塔、循泵房等布置场地有限,通过优化循环水冷端参数,如机组的设计背压、凝汽器的面积、循环水的最佳冷却倍率和循泵特性等,找到最佳冷端设备配置,使得机组在最佳的"机组多维工况点"运行,一方面保证机组的热耗最低、出力最大;另一方面要求冷端设备的投资和运行费用最省,从而降低工程造价,保证机组长期经济运行。 A gas turbine expansion project, uses the Mitsubishi units as its main engine, and its cooling tower and circulating water pump station layout space are limited, through the parameters optimization of circulating water cold end, as design back-pressure of the unit, section of condenser, optical cooling ratio of circulating water and the character of circulation pump etc., we find the optical configuration of cold end, to make the unit running at the optical operation point, it ensures the lowest host consumption and most powerful, and requires lowest investigation of cold end equipment and operating cost, so as to reduce the project cost, and ensure the long-term economic operation of the unit.
作者 王建东 付涛
出处 《工程建设与设计》 2017年第24期61-62,共2页 Construction & Design for Engineering
关键词 燃机 循环水 冷端 参数优化计算 gas turbine circulating water cold end parameter optimization calculation
  • 相关文献

参考文献2

二级参考文献12

  • 1王元文,陈连.管壳式换热器的优化设计[J].贵州化工,2005,30(1):27-28. 被引量:16
  • 2DL/T5339-2006火力发电厂水工设计规范[S].
  • 3杨平正.大型机组多背压凝汽器的研究[R].西安:西北电力设计院,2006.
  • 4徐传海.多背压凝汽器选型计算及建议[R].武汉:中南电力设计院,2005.
  • 5任一峰.多背压凝汽器浅论[R].上海:上海动力设备有限公司,1999.
  • 6龙国庆.冷却端优化专题报告[R].广州:广东省电力设计院,2006.
  • 7石书雨.火力发电厂冷端系统优化分析[D].北京:华北电力大学,2008.
  • 8Y. Haseli, I. Dincer, G. F. Naterer. Optimum temperatures in a shell and tube condenser with respect to exergy [ J ]. International Journal of Heat and Mass Transfer, 2008, (9 - 10) : 2462 -2470.
  • 9GB50050-95.工业循环冷却水处理设计规范[S].[S].,..
  • 10吴双应,牟志才,刘泽筠.换热器性能的经济评价[J].热能动力工程,1999,14(6):437-440. 被引量:16

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部