期刊文献+

闭式水源热泵空调系统制冷工况分析

Analysis of the Closed Water Source Type Heat Pump Air Conditioning System Under the Refrigeration Condition
下载PDF
导出
摘要 介绍了闭式水源热泵空调系统能耗的影响因素,对水源热泵机组定温差、变工况运行时蒸发器侧水温与冷凝器侧制冷剂温度对机组性能的影响进行分析,并根据工程实际对机组性能的数学模型做了修正。 The paper describes the influence factors of energy consumption for air conditioning system of closed water source type heat pump, and analyzes the influence of fixed temperature difference of water source heat pump units end water temperature around evaporator and refrigerant temperature around condense under variable condition runtime on the unit performance. Lastly, it corrects the mathematical model for the unit performance according to the engineering practice.
出处 《工程建设与设计》 2017年第24期68-69,共2页 Construction & Design for Engineering
基金 重庆市基础与前沿研究计划项目:环形水气自激振荡脉冲射流泵传能效率优化及实验研究(cstc2014jcyj A90003)
关键词 闭式水源热泵空调 EER 套管式换热器 air conditioning system of closed water source type heat pump EER heat exchanger of sleeve type