摘要 本文通过X-射线粉末衍射(powder X-ray diffraction,PXRD)K值法定量分析钴粉中α-Co的含量,测定时选用纯α-Co作为标样,α-Al_2O_3为参比物质,测得K值为4.58,并用此K值测定3批样品钴粉中α-Co的含量,结果较为准确,相对标准偏差分别为0.49、0.59、1.16,加标回收率分别为99%、99.43%、99.93%.该方法具有方便快速、简单实用的优点,适用于工厂中不同晶型钴粉的快速定量分析. K value method of X ray powder diffraction was used to quantify the α Co with the hcp structure in cobalt. In this article,α Al2O3 was chosen to be the reference material while the α-Co with high purity as the standard sample. The results showed that K- value was 4.58 which was used to quantify the α -Co in 3 cobalt samples. The relative standard deviation and the recovery rate of 3 cobalt samples evaluate the accuracy of the K- value method.
出处 《南京师大学报(自然科学版)》 CAS CSCD 北大核心 2017年第4期93-97,102,共6页 Journal of Nanjing Normal University(Natural Science Edition)
基金 江苏省大型科学仪器设备共享服务平台资助(BZ201403)
关键词 X-射线粉末衍射 K值法 钴粉 X-ray powder diffraction,α-value method, cobalt