期刊文献+

主动机器人系统在人工全髋关节置换术中的应用 被引量:6

Application of active-robotic system in total hip joint replacement
原文传递
导出
摘要 目的探讨主动式机器人系统在全髋关节置换术中的应用价值及技术要点。方法以2017年8月河南省人民医院骨科收治的5名(纳入标准为:股骨头坏死骨循环研究协会分期(ARCO)ⅡC-Ⅳ期;排除标准:重度骨质疏松症、脑卒中后遗症、关节骨性强直等)拟接受单侧全髋关节初次置换的股骨头坏死患者为研究对象进行前瞻性研究,将CT扫描数据录入术前规划系统(TPLAN)后进行术前规划。切后外侧入路进行显露,使用术中动力系统(TCAT)依次进行股骨侧注册、股骨侧切骨、髋臼侧注册、髋臼侧磨挫,完成操作后安装假体。结果所有5名患者手术过程顺利,术后复查片假体位置良好,双下肢等长,术后2 d拄拐下床活动,随访期间无并发症。结论主动式全髋关节机器人系统可以提高髋关节置换手术的精准度,获得更优的髋关节重建结果,初步体会在初次全髋关节置换手术中具有良好应用前景。 Objective To investigate the application of active robot assisted total hip joint replacement ( THR ) ,as well as the critical techniques .Methods Five patients addmited in Henan People' s Provincial Hospital since August ,2017 were included in the study .Inclusion criteria was necrosis of femoral head staged from ⅡC to Ⅳ the Association Research of Circulation Osseous ( ARCO ) classification.Exclusion criteria was severe osteoporosis ,cerebral apoplexy ,and bony ankylosis .All the five patients underwent THA with posterior-lateral approach .The operation using active robotic system included the registration of femur ,osteotomy and reaming of femur ,registration of actabullum ,bone preparation of femur ,and implantation of prosthesis .Results All the five patients got well rehabilitation following the operation .X-ray showed satisfactory outcome of implants position and limb discrepancy .No complication was found during the follow-up.Conclusion The active robotic system is conducive to the precise bone-cutting and implantation ,and consequently may increase the efficacy of THR .
出处 《中华关节外科杂志(电子版)》 CAS 2017年第6期641-645,共5页 Chinese Journal of Joint Surgery(Electronic Edition)
基金 河南省医学科技攻关计划省部共建项目(201701017)
关键词 股骨头坏死 机器人 人工关节 Femur head necrosis Robotics Joint prosthesis
  • 相关文献

参考文献2

二级参考文献18

  • 1杨连平,李彦生,张练平,马宇锋,葛儒林,杨久承,孙坚.应用CAD/CAM技术进行个体化下颌骨重建[J].中国口腔颌面外科杂志,2004,2(2):65-68. 被引量:41
  • 2Harris WH.Traumatic arthritis of the hip after dislocation and acetabular fractures:treatment by mold arthroplasty.An end-result study using a new method of result evaluation.J Bone Joint Surg Am,1969,51:737-755.
  • 3Zhang H,Huang Y,Zhou YX,et al.Acetabular medial wall displacement osteotomy in total hip arthroplasty:a technique to optimize the acetabular reconstruction in acetabular dysplasia.J Arthroplasty,2005,20:562-567.
  • 4Garcia-Cimbrelo E,Tapia M,Martin-Hervas C.Multislice computed tomography for evaluating acetabular defects in revision THA.Clin Orthop Relat Res,2007,463:138-143.
  • 5Zheng G,,Marx A,Langlotz U,et al.A hybrid CT-free navigation system for total hip arthroplasty[].Computer Aided Surgery.2002
  • 6LewinnekGE,LewisJL,TarrR,et al.Dislocations after total hip replacement arthroplasties[].Journal of Bone and Joint Surgery British Volume.1978
  • 7Kalteis T,,Handel M,Bathis H,et al.Imageless navigation for insertion of the acetabular component in total hip arthroplasty:is it as accurate as CT-based navigation[].Journal of Bone and Joint Surgery British Volume.2006
  • 8Leenders T,Vandevelde D,Mahieu C,et al.Reduction in abduc-tion using computer assisted variability of acetabular cupsurgery:a prospective and randomizedstudy[].Computer Aided Surgery.2002
  • 9Geles PMC,Gerritsen FA.The use of pre-and intraoperative images for surgical guidance[].RBM.1997
  • 10Hichard WD,Zar DM,lapresto EL,et al.A low-cost PCL-bus-based ultrasound system for use in image guided neurpsurgery[].IEEE Transactions on Biomedical Engineering.1999

共引文献7

同被引文献45

引证文献6

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部