期刊文献+

步进梁式加热炉板坯跑偏的影响因素分析及解决方案

Analysis and Solution to Deviation of Slab in Walking Beam Reheating Furnace
下载PDF
导出
摘要 步进梁式加热炉的板坯跑偏量是一项非常重要的加热炉考核指标。通过对步进梁式加热炉的机械设备、液压系统及电气控制等进行为期一个多月的调试和排查,并从制造、安装和调试三个方面对步进梁式加热炉板坯跑偏的影响因素进行分析,为快速准确地解决板坯跑偏问题提出了解决方案。 The deviation of slab is a crucial performance guarantee for walking beam reheating furnace. Through the commissioning and inspection on mechanical equipment,electrical control and hydraulic system for walking beam reheating furnace for over one month,the author had found the key factors which affect the deviation of slab and proposed efficient and accurate solution to solve the deviation of slab through three aspects of manufacturing,installation and commissioning.
作者 熊邦耀
出处 《工业加热》 CAS 2017年第6期21-24,28,共5页 Industrial Heating
关键词 步进梁式加热炉 板坯跑偏 影响因素 制造 安装 调试 解决方案 walking-beam reheating furnace deviation of slab affection factor manufacture installation commissioning solution
  • 相关文献

参考文献3

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部