期刊文献+

Temperature rise induced by an annular focused transducer with a wide aperture angle in multi-layer tissue

Temperature rise induced by an annular focused transducer with a wide aperture angle in multi-layer tissue
下载PDF
导出
摘要 In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time monitoring and control of the treatment. In this paper, the spheroidal beam equation (SBE) was used to calculate the sound lield by an annular focused transducer with a wide aperture angle to first derive the heat deposition and the Pennes equation was used to calculate the temperature field in multi-layer tissue. We studied the effect of different parameters on the temperature of the tissues. The result shows that the focal length has a significant influence on both maximum liver temperature rise and skin temperature rise, and both increase with the increase in the focal length. When the frequency increases, the temperature rise first undergoes a rapid increase before gradually reaching a maximum, and then finally decreasing. The temperature rise increases while the inner radius decreases or the sound pressure increases. By choosing suitable parameters, the proper temperature rise both on the target tissue and skin via an annular tbcused transducer with a wide aperture angle can be obtained. In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time monitoring and control of the treatment. In this paper, the spheroidal beam equation (SBE) was used to calculate the sound lield by an annular focused transducer with a wide aperture angle to first derive the heat deposition and the Pennes equation was used to calculate the temperature field in multi-layer tissue. We studied the effect of different parameters on the temperature of the tissues. The result shows that the focal length has a significant influence on both maximum liver temperature rise and skin temperature rise, and both increase with the increase in the focal length. When the frequency increases, the temperature rise first undergoes a rapid increase before gradually reaching a maximum, and then finally decreasing. The temperature rise increases while the inner radius decreases or the sound pressure increases. By choosing suitable parameters, the proper temperature rise both on the target tissue and skin via an annular tbcused transducer with a wide aperture angle can be obtained.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第1期390-395,共6页 中国物理B(英文版)
基金 Project supported by the National Key Research and Development Program,China(Grant No.2016YFF0203000) the National Natural Science Foundation of China(Grant Nos.11774167 and 61571222) the Fundamental Research Funds for the Central Universities,China(Grant No.020414380001) the State Key Laboratory of Acoustics,Chinese Academy of Sciences(Grant No.SKLA201609) AQSIQ Technology Research and Development Program,China(Grant No.2017QK125)
关键词 spheroidal beam equation annular focused transducer multi-layer tissue temperature field spheroidal beam equation, annular focused transducer, multi-layer tissue, temperature field
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部