X荧光分析法测定地表灰尘和空调灰中重金属含量 被引量:2

Determination of heavy metal content in dust of earth's surface and dust on air conditioner filter by X-ray fluorescence analysis
下载PDF
导出
摘要 使用X荧光分析法对地表灰尘和空调滤网灰中所含金属元素(Mn,Fe,Cu,Zn,Pb)做了定量分析.结果表明,5种元素在空调灰中的含量都大于其在地表灰尘中的含量,其中Cu,Zn,Pb 3种元素在地表灰尘和空调灰中的含量远远大于四川省表层土壤中对应的平均含量.通过对不同粒径组地表灰尘中重金属含量的分析表明,地表灰尘中五种元素的含量在测量范围内随灰尘直径的变化规律大致相同. The dust of earth's surface and the dust on air conditioner filters reflect a certain area of air pollution in a period of time. In the present study, we investigate the dust collected from the Wangjiang campus of Sichuan University on March,2017. The dust is divided into 9 groups according to their diameters. The dust is made into the samples by mixing the dust and analytically pure starch at a ratio of 1 : 2, and pressing it into slices of 1.5 cm in radius and 6 mm in thickness through using a powder compressor. Likewise, the salts(MnSO4·H2O, Fe(NO3)3·9 H2O, Cu SO4·5 H2O, ZnSO4·7 H2O,Pb(NO3)2), are also made into standard samples of different elements(Mn, Fe, Cu, Zn, and Pb). X-ray fluorescence analyzer is used to measure the element content in each of the samples according to calibration curves measured from the standard samples. The results show that the content of each element in the earth's surface dust is lower than that in the dust on the air conditioner filter. The values of Cu, Zn, and Pb content in the dust are higher than the average content of the topsoil in Sichuan Province, China. These elements possibly originate from motor vehicle exhaust.Based on the theoretical model for the gaseous elements to change into the fine particulate matter, the change of the trace element content with the particle size can be expressed as Ci∝ ki D-n, where Ciis the content of the metal element i in the dust, kiis a scale factor, D is the diameter of the dust particle, and n is the distribution index. From the results it is concluded that the distribution indexes corresponding to various elements are approximately the same in the size range of interest to us(32.5–230 μm). A recommended value of n is-0.43±0.06.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2018年第1期46-52,共7页 Acta Physica Sinica
关键词 灰尘 X荧光分析 重金属含量 灰尘粒径 dust, X-ray fluorescence analysis, heavy metal content, diameter size
  • 相关文献

参考文献5

二级参考文献82

共引文献168

同被引文献42

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部