摘要
本文根据胆囊收缩素(CCK)在生理浓度下可刺激离体胰腺泡分泌淀粉酶的特性,来测定血浆CCK浓度。此方法不受血浆中胃泌素的干扰,可反映全部有生物活性的CCK分子,灵敏度为0.86pmol/L CCK-8当量。本文对11例正常人空腹及餐后血浆CCK浓度进行了测定。
A sensitive and specific bioassay for the measurement of plasma cholecysto-kinin (CCK) is reported. CCK was extracted from plasma by SEP-PAK cartridges and the extracts were measured for CCK levels based on their ability to stimulate amylase release from dispersed rat pancreatic acini. Plasma CCK levels as low as 0.86 pmol/L (CCK-8 equivalent) were detectable. Gastrin in physiological concentration did not affect the bioassay. The amylase release stimulated by plasma extracts was abolished by Bt2-cGMP, a specific CCK receptor antagonist, indicating that there might be no secretin or VIP in plasma extracts. With this bioassay, fasting and postprandial plasma CCK levels of 11 normal volunteers were determined. The fasting level of CCK was 0.95±0.22 pmol/L (X±SE). It increased to 2.98±0.67 pmol/L 15 minutes after feeding and remained significantly higher than the fasting level during a 60-minute period.
出处
《中国医学科学院学报》
CAS
CSCD
北大核心
1991年第6期417-421,共5页
Acta Academiae Medicinae Sinicae
基金
国家自然科学基金
青年基金