摘要
分析了陕西中部地区某四塔合一间冷超临界机组反渗透设备试运过程中的污染等诸多问题。该机组以反渗透系统对已处理的城市中水进行过滤作为离子交换除盐系统的水源,在试运过程中发现诸多问题,经过现场分析提出了合理科学的解决方案,取得了非常良好的效果。
This paper analyzed the causes of contamination of the reverse osmosis system during commissioning. This equipment used processing reclaimed water in the central region of Shaanxi province as the water source of ion-exchange unit system. During field analysis put forward a reasonable scientific solution,and achieved very good results.
出处
《清洗世界》
CAS
2017年第12期23-27,共5页
Cleaning World
关键词
反渗透
中水
污染
reverse osmosis system
reclaimed water
contamination