期刊文献+

Exergy analysis of R1234ze(Z) as high temperature heat pump working fluid with multi-stage compression 被引量:8

Exergy analysis of R1234ze(Z) as high temperature heat pump working fluid with multi-stage compression
原文传递
导出
摘要 In this paper, the simulation approach and exergy analysis of multi-stage compression high tempera- ture heat pump (HTHP) systems with R1234ze(Z) working fluid are conducted. Both the single-stage and multi-stage compression cycles are analyzed to compare the system performance with 120℃ pressurized hot water supply based upon waste heat recovery. The exergy destruction ratios of each component for different stage compression systems are compared. The results show that the exergy loss ratios of the compressor are bigger than that of the evaporator and the condenser for the single-stage compres- sion system. The multi-stage compression system has better energy and exergy etticiencies with the increase of compression stage number. Compared with the single- stage compression system, the coefficient of performance (COP) improvements of the two-stage and three-stage compression system are 9.1% and 14.6%, respectively. When the waste heat source temperature is 60℃, the exergy efficiencies increase about 6.9% and 11.8% for the two-stage and three-stage compression system respec- tively. In this paper, the simulation approach and exergy analysis of multi-stage compression high tempera- ture heat pump (HTHP) systems with R1234ze(Z) working fluid are conducted. Both the single-stage and multi-stage compression cycles are analyzed to compare the system performance with 120℃ pressurized hot water supply based upon waste heat recovery. The exergy destruction ratios of each component for different stage compression systems are compared. The results show that the exergy loss ratios of the compressor are bigger than that of the evaporator and the condenser for the single-stage compres- sion system. The multi-stage compression system has better energy and exergy etticiencies with the increase of compression stage number. Compared with the single- stage compression system, the coefficient of performance (COP) improvements of the two-stage and three-stage compression system are 9.1% and 14.6%, respectively. When the waste heat source temperature is 60℃, the exergy efficiencies increase about 6.9% and 11.8% for the two-stage and three-stage compression system respec- tively.
出处 《Frontiers in Energy》 SCIE CSCD 2017年第4期493-502,共10页 能源前沿(英文版)
关键词 multi-stage compression high temperatureheat pump heat recovery exergy destruction R1234ze(Z) working fluid multi-stage compression, high temperatureheat pump, heat recovery, exergy destruction,R1234ze(Z) working fluid
  • 相关文献

同被引文献94

引证文献8

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部