摘要 以广东省某电厂1号、2号(2×700MW)机组超低排放改造湿式除尘器工程为例,介绍了改造项目技术路线的选择、布置方案、设计特色。实例表明,金属平板式湿式电除尘能够使电厂实现稳定超低排放的要求。 By taking the WESP reform project of ultra-low emission for Unit 1# and Unit 2# (2×700 MW) in a certain Power Plant of Yuedian Group of Guangdong Province as an example, this paper presents the choice, layout and design features of technical route of reform project. The researches show that the metal-plate-type WESP is able to satisfy the requirements of the stable ultra-low emission.
作者 罗如生 余伟权 林国鑫 程国辉 陈艺聪 林翔 郑岩峰 LUO Ru-sheng;YU Wei-quan;LIN Guo-xin;CHENG Guo-hui;CHEN Yi-cong;LIN Xiang;ZHENG Yan-feng(Fujian Long Net Environmental Protection Co., Ltd, Longyan Fujian 364000;Guangdong Electric Group Co., Ltd, Zhuhai Guangdong 519000, China)
出处 《中国环保产业》 2018年第1期35-39,共5页 China Environmental Protection Industry
关键词 金属平板式湿式电除尘 超低排放 协同治理 metal-plate-type WESP ultra-low emission coordination treatment