摘要 建立基于QuEChERS前处理方法和气相色谱-电子捕获检测器同时测定贝类样品中17种持久性有机污染物残留的方法。样品经QuEChERS法进行预处理,选用已腈为提取剂,N-丙基乙二胺(PSA):C18(4∶6,m/m)净化,外标法定量。17种持久性有机污染物在1.0~50.0μg/kg范围内质量浓度与峰面积呈现良好的线性关系,相关系数均大于0.9957。17种持久性有机污染物的方法检出限(信噪比为3)和定量限(信噪比为10)分别为0.01~0.25μg/kg和0.25~1.0μg/kg。添加浓度为10.0、15.0、25.0μg/kg时,17种持久性有机污染物的平均回收率为84.1%~119.2%,相对标准偏差为3.9%~12.6%。本方法具有快速简便、定量准确,可应用于贝类样品中17种持久性有机污染物的快速检测。 A modified QuEChERS method coupled with GC-ECD was used to establish a method for the simultaneous determination of 17 persistent organic pollutants in marine products. The acetonitrile was selected as the extraction solvent,and N-propyl ethylenediamine (PSA) : C18 (4 : 6,m/m)was optimized for purification. Under the optimal conditions,the excellent linear correlation was obtained in the range of 1.0-50.0 μg/kg with the R2 above 0.9957. The limit of detection (S/N=3) and the limit of quantification (S/N=I0) were 0.01-0.25 μg/kg and 0.25-1.0 μg/kg,respectively. Meanwhile,the recoveries in the range of 84.1%-119.2% were obtained at the spiked concentrations of 10.0, 15.0,25.0 μg/kg with the relative standard deviation of 3.9%-12.6%. These findings demonstrate that the applicability of the developed method for quickly determination of 17 POPs in shellfish samples.
出处 《水产养殖》 CAS 2018年第1期29-35,共7页 Journal of Aquaculture
基金 海洋公益性行业专项科研基金(201405035) 国家自然科学基金(No.31372572) 宁波市科技创新团队项目(2015C110018)
关键词 QUECHERS 气相色谱-电子捕获检测器 贝类样品 QuEChERS GC-ECD Shellfish samples
  • 相关文献

参考文献6

二级参考文献75

共引文献54

同被引文献113

引证文献7

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部