城市轨道交通的能耗巨大,而其中通风空调系统的设备能耗占据相当大的一部分,在全面响应国家节能号召的情况下,设计者应系统地考虑高架车站通风空调系统的节能措施及运行方案。本文以运营的南京地铁宁天线某高架车站为例,通过对通风空调系统的划分,节能设计,防排烟设计,来探讨轨道交通高架车站通风空调设计的方法,为以后轨道交通设计者提供参考。
The energy consumption of city track transportation is huge,and the energy consumption of the air conditioning and ventilation system equipment accounted for a considerable part.In the situation of energy saving,designers should consider energy saving measures and operation scheme of elevated station air conditioning and ventilation system.This article describes the operated Nanjing Metro S8 Line for an elevated station,through to the division of ventilation and air conditioning system,energy saving design,the design of smoke control,to explore the method of elevated rail transit station ventilation and air conditioning design, provide a reference for the designer of rail transit.
出处
《北方建筑》
2018年第1期31-34,共4页
Northern Architecture
关键词
通风空调
高架车站
节能设计
ventilation and air conditioning
elevated station
energy saving design