摘要
以华电莱州发电有限公司2×1 000 MW燃煤机组为例,介绍了空气预热器快速减负荷(RB)的事件经过,分析了空气预热器跳闸的原因,给出了防范空气预热器跳闸的具体措施,保证了机组安全运行。
Based on the example of Huadian Laizhou Power Generation Company Limited's 2 × 1 000 MW coal-fired unit,the incident of air preheater runback( RB) was introduced. Analyzing the cause of the trip,detailed preventive measures were provided,which can secure the operation of the unit.
出处
《华电技术》
CAS
2018年第1期22-26,共5页
HUADIAN TECHNOLOGY