传统监控软件不能根据被监控对象在真实运行环境下的状态变化自动化判断设备正常和异常情况,只能采用简单阀值告警的方式已经越来越不适合电力系统对IT设备监控的要求。本文通过数据基线的研究,探讨根据IT设备在真实运行环境下的状态变化,自动形成数据偏离基线,结合时间参数来判断设备是否出现异常的方法。
The traditional monitoring software can not automatically judge the normal and abnormal situation of the equipment according to the state change of the monitored object in the real running environment. The method of simple threshold alarm has become more and more unsuitable for the monitoring of IT equipment in power system. Through the research of data baseline, this paper discusses the change of the state of IT equipment in real operation environment. Automatic data deviation from the baseline, combined with time parameters to determine whether the equipment is abnormal.