摘要
为了讨论PGAI技术分析的准确性,并验证冷中子和热中子应用于PGAI技术的可行性,通过蒙特卡罗模拟计算软件对PGAI技术理想化模型进行了研究,采用高准直的冷中子及热中子束和高纯锗探测器,对一块5cm×5cm×1cm均匀铁单质样品进行了模拟计算及图像重建,选取的等效体积大小为1cm×1cm×1cm。结果显示:两种能量中子可以用于PGAI技术实现元素分布测量,但无论使用何种能量中子,由于物料体效应带来的中子自屏效应、中子散射效应以及伽马射线自吸收作用,即便在对均匀单质样品进行测量时,图像重建结果也无法保证各位置元素响应的一致性。因此,在后续工作中,需理清PGAI物理机制,建立相应的修正模型。
Prompt gamma activation imaging(PGAI)is a new type of element distribution imaging method in a non-destructive way.At present,the PGAI measure platforms which have been completed are all applied under the ideal model,and only for analyzing small pieces of sample by using the neutron source at the reactor.To discuss the accuracy and validate the feasibility of PGAI technology based on cold and thermal neutron,the ideal model of PGAI was analyzed by using Monte Carlo software.A homogeneous sample of 5 cm×5 cm×1 cm which consisted of pure iron was measured by adopting collimated neutron beam and the high-purity Ge detector,the dimension of the isovolume was 1 cm×1 cm×1 cm.It is shown that two kinds of energy neutrons all has been successfully used in PGAI.But no matter what kind of energy neutrons,when measuring the homogeneous single element sample,the consistency of image reconstruction results can't be guaranteed because of the neutron self-absorption,neutron scattering andγ-ray self-absorption.Therefore we need to analyze the physical mechanism and establish proper correction model in our later work.
出处
《强激光与粒子束》
EI
CAS
CSCD
北大核心
2018年第1期148-152,共5页
High Power Laser and Particle Beams
基金
国家自然科学基金项目(GBA1501401)
关键词
瞬发伽马射线成像
蒙特卡罗
图像重建
中子散射
中子自屏
prompt gamma activation imaging~ Monte Carlo
reconstruction image
neutron scatter
neutron selfabsorption