PGAI瞬发伽玛射线活化成像技术理想化模型的模拟 被引量:3

Prompt gamma activation imaging technology under idealized model
下载PDF
导出
摘要 为了讨论PGAI技术分析的准确性,并验证冷中子和热中子应用于PGAI技术的可行性,通过蒙特卡罗模拟计算软件对PGAI技术理想化模型进行了研究,采用高准直的冷中子及热中子束和高纯锗探测器,对一块5cm×5cm×1cm均匀铁单质样品进行了模拟计算及图像重建,选取的等效体积大小为1cm×1cm×1cm。结果显示:两种能量中子可以用于PGAI技术实现元素分布测量,但无论使用何种能量中子,由于物料体效应带来的中子自屏效应、中子散射效应以及伽马射线自吸收作用,即便在对均匀单质样品进行测量时,图像重建结果也无法保证各位置元素响应的一致性。因此,在后续工作中,需理清PGAI物理机制,建立相应的修正模型。 Prompt gamma activation imaging(PGAI)is a new type of element distribution imaging method in a non-destructive way.At present,the PGAI measure platforms which have been completed are all applied under the ideal model,and only for analyzing small pieces of sample by using the neutron source at the reactor.To discuss the accuracy and validate the feasibility of PGAI technology based on cold and thermal neutron,the ideal model of PGAI was analyzed by using Monte Carlo software.A homogeneous sample of 5 cm×5 cm×1 cm which consisted of pure iron was measured by adopting collimated neutron beam and the high-purity Ge detector,the dimension of the isovolume was 1 cm×1 cm×1 cm.It is shown that two kinds of energy neutrons all has been successfully used in PGAI.But no matter what kind of energy neutrons,when measuring the homogeneous single element sample,the consistency of image reconstruction results can't be guaranteed because of the neutron self-absorption,neutron scattering andγ-ray self-absorption.Therefore we need to analyze the physical mechanism and establish proper correction model in our later work.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2018年第1期148-152,共5页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(GBA1501401)
关键词 瞬发伽马射线成像 蒙特卡罗 图像重建 中子散射 中子自屏 prompt gamma activation imaging~ Monte Carlo reconstruction image neutron scatter neutron selfabsorption
  • 相关文献

参考文献4

二级参考文献25

  • 1陈宝山.我国压水堆核电燃料元件的发展[J].原子能科学技术,2003,37(z1):10-14. 被引量:8
  • 2貊大卫,刘以思,蔡庆胜,陈伯显,刘克斌,舒君.中子照相检验航天导爆索的研究[J].核电子学与探测技术,1995,15(2):88-91. 被引量:3
  • 35貊大卫,刘以思,金光宇等.中子照相,北京:原子能出版社,1996
  • 4魏宝杰,钟海明.中子管及其应用技术,长春:东北师范大学出版社,1997
  • 5S. Fujine, K. Yoneda, K. yoshii, et. al., Development of imaging techniques for fast neutron radiography in Japan, Nucl. Instr. and Meth. 1999, A424:190 ~ 199
  • 6V. Mikerov, W. Waschkowski, Fast neutron fields imaging with a CCD-based luminescent detector, Nucl. Instr. and Meth. 1999, A 424:48 ~ 52
  • 7Toshiya Sanami, Mamoru Baba, Keilichiro Saito, et. al., Fastneutron profiling with an imaging pkate, Nucl. Instr. and Meth 2001, A458: 720 ~ 728
  • 8M. Matsubayashi, T. Hibiki, K. Mishima, et. al., Preliminary examination of the applicability of imaging plates to fast neutron radiography, Nucl. Instr. and Meth: 2001, A463: 324 ~ 330
  • 9T.Tamaki et al. ,Proc. WCNR-5,1997,391
  • 10裴宇阳,唐国有,郭之虞.快中子照相胶片成像法的初步实验,第十二界全国核物理大会