期刊文献+

涡轮机启动失败故障分析与处理

Analysis and Troubkshooting for Turbine Startup Failure
下载PDF
导出
摘要 在分析和处理涡轮机启动失败故障时,技术人员熟练运用燃烧三要素的基本知识,使得处理思路清晰、方向准确,该方法能为相关技术人员在解决此类问题时提供理论参考,这既是技术人员长期实践的结果,也是技术人员专业知识灵活运用的良好实践。通过对海上某油田涡轮机启动失败多种现象的分析,得出结论:凡要保证内燃机顺利启动,必须保证机组所处的环境温度在20~25,℃,最终通过细致的排查将问题处理,其过程讲解详实处理得当。 When dealing with turbine start-up failures,the skillful use of the basic knowledge of the three elements of combustion enables technicians have a clear mind and a correct direction of problem solving.The method provides theoreti-cal reference for related technical personnel in dealing with such problems.This is a not only the long-term practice of tech-nical personnel,but also the good practice of their professional knowledge.Based on the analysis of various phenomena ofoffshore oilfield turbine start-up failure,it comes to a conclusion that to ensure the start operation of the internal combustionengine,the environment temperature must be within the range of 20~25,℃.The issues have been solved through careful investigation.The detailed explanation may provide some help to related technical personnel.
作者 赵伟 ZHAO Wei(Liaodong Operating Company at Tianjin Branch Company Co.,LTD. of CNOOC,Tianjin 300457,Chin)
出处 《天津科技》 2018年第2期64-65,68,共3页 Tianjin Science & Technology
关键词 燃烧三要素 启动故障 点火失败 故障排查 key elements of combustion startup failure failure of ignition troubleshooting