期刊文献+

电缆低温敷设外护套开裂影响因素分析及力学仿真 被引量:1

Analysis of Factors of the Cable Outer Sheath Cracking and Mechanical Simulation
下载PDF
导出
摘要 结合护套材料的物理机械性能、护套挤出的工艺、外部机械力的作用、环境的作用、结构尺寸5个方面进行了电缆敷设过程中护套开裂影响因素分析,对电缆低温敷设过程中电缆存在内部毛刺和外部毛刺2种情况进行了力学仿真分析,提出预防电缆低温敷设过程中防止电缆外护套开裂的措施:严格控制敷设程序及敷设工艺,强化电缆外护套抗寒性,避免冲击和不必要剐蹭等。 The influence factors of sheath cracking in cable laying process are analyzed from 5 aspects of physical and mechanical properties, jacket extrusion process, external mechanical force, environmental function and structure size. Mechanical simulation analysis is made for two cases of internal burrs and external burrs of cables during low temperature laying process, and measures for preventing cable outer sheath cracking are put forward to prevent cable from being laid at low temperature, strictly control the laying procedure and laying process, strengthen the cold resistance of the outer sheath of the cable, avoid the impact and unnecessary scraping, etc.
出处 《吉林电力》 2018年第1期49-53,共5页 Jilin Electric Power
关键词 电缆外护套 低温 敷设 开裂 力学仿真 cable outer sheath low temperature laying cracking mechanical simulation
  • 相关文献

参考文献4

二级参考文献13

  • 1王春江.电线电缆手册(第二版)[M].北京:机械工业出版社,2001.509.
  • 2卓金玉.电力电缆设计原理[M].北京:机械工业出版社,1998.
  • 3GB/T15065--2009电线电缆用黑色聚乙烯塑料[S].
  • 4GB50168--2006电气装置安装工程电缆线路施工及验收规范[S].
  • 5GB/Z18890--2002额定电压220kV(Um=252kV)交联聚乙烯绝缘电力电缆及其附件[S].
  • 6IEC 60502-1 : 2009 Power cables with extruded insulation and their accessories for rated voltages from 1 kV ( Um = 1.2 kV) up to 30 kV ( Um = 36 kV) - Part 1 : Cables for rated voltages of 1 kV (Um=1.2 kV) and3 kV (Um=3.6 kV) [S].
  • 7GB/T18380--2008电缆和光缆在火焰条件下的燃烧试验[S].
  • 8GB/T17651--1998电缆或光缆在特定条件下燃烧的烟密度测定[S].
  • 9IEC 61034-2:2005 Measurement of smoke density of cables burn- ing under defined conditions-Part 2 : Test procedure and require- ments [ S ].
  • 10GB/T2951.13-2008电缆和光缆绝缘和护套材料通用试验方法第13部分:通用试验方法-密度测定方法-吸水试验-收缩试验[S].