摘要 本文通过采用NX 8.5软件进行三维建模和ANSYS Workbench分析软件对某热塑性材料躯壳专用接触器的结构强度进行研究分析,重点对现有产品出现问题的部位进行评估,并采用实物样品进行了试验确认。然后通过结构上的改进,并采用创新专利方案的应用得到改进后的热固性材料躯壳专用接触器,同样采用相同方式对改进后接触器结构强度进行研究分析和试验验证,评价确认了改进方案有效。 This thesis researches and analyzes one thermoplastic body DP contactor's structure strength by using NX 8.5 software to do 3D modeling and ANSYS Workbench analyzing software,focuses on evaluating the part with problem and testing contactor samples for verification. And then adopt the same way to make investigation, analysis and test verifi- cation on structure strength of the thermoset body contactor with improved structure and using innovative patent scheme, and confirms the improved scheme is effective.
作者 张协利
出处 《电气开关》 2018年第1期28-31,36,共5页 Electric Switchgear
关键词 专用接触器 热塑性材料 热固性材料 结构强度分析 DP contactor thermoplastic material thermoset material structural strength anslysis
  • 相关文献

参考文献4

二级参考文献12

  • 1荣命哲,娄建勇,王小华.永磁式接触器动触头动作特性仿真分析与试验研究[J].中国电机工程学报,2005,25(1):109-113. 被引量:72
  • 2陈志刚,吴雪飞.基于Pro/E及Adams圆柱齿轮减速器的参数化建模及运动仿真[J].机械研究与应用,2005,18(2):105-106. 被引量:21
  • 3王峰,苏秀苹,张凯.基于阿ANSYS/ADAMS的交流接触器机构动力学仿真的研究[J].电气应用,2006,25(7):27-30. 被引量:18
  • 4[3]Masayoshi Wada,Hiroshi Yoshimoto,Yujiro Kitaide.Dynamic analysis and simulation of electromagnetic contactors with AC solenoids[C].Proceedings of the 28th Annual Conference of the IEEE Industrial Electronics Society,Nov 5-8,2002,4:2745 -2751.
  • 5[4]R Gollee,G Gerlach.An FEM-based method for analysis of the dynamic behavior of AC contactors[J].IEEE Transactions on Magnetics,2000,36 (4):1337-1340.
  • 6[5]Mark A Juds,John R Brauer.AC contactor motion computed with coupled electromagnetic and structural finite elements[J].IEEE Transactions on Magnetics,1995,31 (6):3575-3577.
  • 717B/1689/NP低压开关设备和控制设备用于信息交换的产品数据和特性[S].
  • 817B/1697/CDIEC61915-2低压开关设备和控制设备-网络工业设备的设备描述第2部分:起动器及类似设备的根设备描述[S].
  • 9ARI Standard 780/790 -1997, Definite Purpose and Limited Duty Definite Purpose Magnetic Contactor, 1997[S].Air-conditioning and Refrigeration Institution, 4301, North Fairfax Drive, Suite 425, Arlington, VA 22203, U.S.A.
  • 10UL Standard for safety 508, Industrial Control Equipment ,Seventeenth Edition, 1999[S].Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062, U.S.A.