摘要 500 k V主网短路电流超标问题已成为广东电网近年来运行最突出的问题之一。现有的运行措施可将超标站点短路电流暂时降低至安全水平,但电网整体的短路电流水平仍较高,且牺牲了部分系统安全可靠性,从长远来看通过直流背靠背异步互联限制短路电流是可行的解决办法。以2018年广东500 k V电网为研究对象,建立直流背靠背异步联网模型,从短路电流限制效果、系统可靠性等方面进行仿真计算,并与传统运行措施进行对比,可以得出,采用直流背靠背异步互联措施具有更好的限流效果和更高的安全可靠性,验证了该方案在短路电流限制方面的有效性和优越性。 The main problem of 500 k V short-circuit current overweight has become one of the most prominent issues of Guangdong power grid in recent years. The existing operation measures can reduce excessive short-circuit current to safe levels temporarily,but the short circuit current level of the whole power grid is still high,with sacrificing the part safety and reliability of the system. In the long run,limiting short-circuit current through the back-to-back HVDC asynchronous interconnection is a feasible solution. Taking Guangdong 500 k V power grid in 2018 as the research object,the model of back-to-back HVDC asynchronous interconnection model is established. And with the simulation of the short circuit current limiting effect and the system reliability,compared with traditional operation measures,we can obtain that back-to-back HVDC asynchronous interconnection has better short circuit current limiting effect and higher safety and reliability. The effectiveness and superiority of the scheme in short-circuit current limiting are verified.
出处 《电测与仪表》 北大核心 2018年第4期40-47,共8页 Electrical Measurement & Instrumentation
关键词 短路电流 直流背靠背 限流措施 限流效果 可靠性 short circuit current back to back DC transmission current limiting measures current limiting effect re liability
  • 相关文献

参考文献12

二级参考文献115

共引文献671

同被引文献77

引证文献8

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部