摘要 为探明西部某气田L245/316L双金属复合管失效原因,采用一系列理化性能检测方法,并结合现场实际工况,进行综合分析。研究表明:焊接过程中焊趾附近Cr、Ni元素稀释,在Cl-的作用下,形成斜向上的腐蚀凹槽;封焊处存在斜向下的微裂纹,而过渡焊区域为高硬度马氏体组织,裂纹一旦扩展将不具备止裂性能;根焊和过渡焊交界处含有气孔夹杂,气孔周围容易产生应力集中。在以上三个因素共同作用下形成刺漏点,腐蚀性介质通过刺漏点与基管直接接触,基管腐蚀减薄至管壁不能承受内压力而爆管。 In order to find out the cause of the failure of L245/316 Lbimetallic composite pipe in a gas field in west China,a series tests for physical and chemical properties combined with the actual working conditions in the field were carried out to comprehensively study and analysize the failure.The results show that the elements of Cr and Ni were diluted near the weld toe during welding process.Corrosion grooves were formed obliquely upward with the effect of Cl-.Micro cracks obliquely downward at the seal weld were found,and the transition welding area had high hardness with martensitic structure.Once the crack extension happened,the welding would not have the ability to stop cracking.The junction between root welding and transition welding contained pore and inclusion,around which stress concentration was easy to appear.Under the joint action of the above three factors,a leaky point was formed,corrosive medium could directly contact with the basic pipe through the leaky point,and the basic pipe wall was reduced because of corrosion until it could not withstand the internal pressure,and then the pipe ruptured.
作者 丁晗 李先明 安超 李磊 杨刚 邝献任 DING Han;LI Xianming;AN Chao;LI Lei;YANG Gang;KUANG Xianren(CNPC Tubular Goods Research Institute, Xi'an 710077, China;Tarim Oil Field, Korla 841000, China)
出处 《腐蚀与防护》 CAS 北大核心 2018年第2期157-161,166,共6页 Corrosion & Protection
关键词 双金属复合管 焊缝 失效 腐蚀 bimetal composite pipe weld failure corrosion
  • 相关文献

参考文献6

二级参考文献82

共引文献111

同被引文献61

引证文献7

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部