期刊文献+

两级交错CRM单相功率因数校正器

Two-channel Interleaved CRM Single Phase Power Factor Corrector
下载PDF
导出
摘要 为提高功率等级和系统效率,充分降低磁件尺寸和缩小成本,单相交流电源供电的变频空调和充电机等用电设备的前级AC/DC功率电路需采用多级交错和临界导电模式(CRM)的单相有源功率因数校正(APFC)技术。在对CRM APFC—些基本问题进行分析后,采用模拟控制器FAN9611实现和测试分析了两级交错CRM APFC样件,支持输出功率6.5kW,效率高达98.4%,仿真结果与实测结果验证了CRM APFC的可行性。 In order to improve the power level and system efficiency, the size of the magnetic components and costs are fully reduced, the former AC/DC power circuits of inverter air conditioner, charger and other electrical equipment with single-phase AC power supply require single-phase active power factor correction (APFC) technology employing multi-channel interleaved and critical conduction mode(CRM).Based on the analysis of some basic problems of CRM APFC,the two-channel interleaved CRM APFC samples are implemented and tested by simulation controller FAN9611. The output power is 6.5 kW and the efficiency is up to 98.4%.The simulation results and the measured results verify the feasibility of CRM APFC.
作者 卢广震 杨喜军 袁乐 LU Guang-zhen;YANG Xi-jun;YUAN Le(Anhui University of Science and Technology, Huainan 232000, China)
出处 《电力电子技术》 CSCD 北大核心 2018年第2期115-117,124,共4页 Power Electronics
基金 国家自然科学基金(U1360203)
关键词 功率因数校正 两级交错 临界导电模式 power factor correction two-channel interleaved critical conduction mode
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部