期刊文献+

隔爆型电动执行机构外壳静压试验分析与仿真 被引量:3

Analysis and Simulation on Hydrostatic Test of Housing Parts for Explosion-Proof Electric Actuator
下载PDF
导出
摘要 使用有限元分析方法,对隔爆型电动执行机构外壳部件进行静压试验仿真模拟。通过建立有限元模型和施加约束及载荷,得到应力、变形分析结果,从而找出结构的薄弱点,优化隔爆结构的设计。相比传统的设计方法,该方法减少了因反复进行静压试验而造成的设计成本增加和周期延长。 The paper simulates the hydrostatic test of housing parts for explosion-proof electric actuator using the analysis method of finite element. It obtains the analysis results of stress and deformation through establishing the finite element model and appling the displacement and load boundary, that can find the weak points and optimize the designing of the explosion-proof structure. Comparing to the traditional designing method, this method could reduce the additional design costs and cycles caused by repeated static pressure test.
作者 张凌云 许健
出处 《机电工程技术》 2018年第1期72-74,109,共4页 Mechanical & Electrical Engineering Technology
关键词 电动执行机构 隔爆 静压试验 应力分析 electric aetuator explosion-proof hydrostatic test stress analysis
  • 相关文献

参考文献6

二级参考文献12

  • 1GB/T700-2006[S].碳素结构钢.中华人民共和国国家质量监督检验检疫总局.
  • 2GB3836.1—2010.爆炸性环境第1部分:设备通用要求[S].
  • 3GB3836.2—2010.爆炸性环境第2部分:由隔爆外壳“d”保护的设备[S].
  • 4GB3836.1-2010.爆炸性环境第1部分:设备通用要求.
  • 5GB3836.3-2010.爆炸性环境第3部分:由增安型“e”保护的设备.
  • 6蒋建.工业防爆实用技术手册[M].沈阳:辽宁科学技术出版社,1996.18.
  • 7GB3836.2-2010爆炸性环境第2部分:由隔爆外壳"d"保护的设备.
  • 8GB12476.1-2013,可燃性粉尘环境用电气设备第1部分:通用要求[S].
  • 9GB12476.5--2013,可燃性粉尘环境用电气设备第5部分:外壳保护型“tD”[S].
  • 10王博生,王建平.浅谈矿用防爆行星齿轮减速起动机设计[J].科技风,2012(1):122-122. 被引量:1