摘要
根据现场腐蚀情况观察,通过化学成分分析,系统的分析了换热器列管腐蚀的原因,结果表明,导致换热器列管腐蚀的基本原因是循环冷却水的垢蚀。
According to the observation of corrosion condition,through chemical composition analysis,this article systematically analyzes the causes of heat exchanger tube corrosion. The results show that the basic cause of heat exchanger tube corrosion is scale and corrosion of circulating cooling water.
出处
《世界有色金属》
2017年第20期11-13,共3页
World Nonferrous Metals
关键词
换热器
腐蚀
heat exchanger
corrosion