某电厂M701F4型联合循环机组一次调频性能不良问题分析与处理 被引量:1

Root Cause Analysis and Poor Performance Processing of Primary Frequency Regulation of an M701F4 Gas Turbine
下载PDF
导出
摘要 本文从某电厂M701F4单轴燃气联合循环机组一次调频性能不满足华东地区电网关于一次调频的规定而被多次考核的问题出发,从5个方面分析可能影响该机组一次调频性能的具体原因。最后给出通过微调机组转速死区和转差-负荷变动量对应函数的方法提高机组一次调频的动作正确率和平均调节性能的解决方案。 After description of an event occours with an M701F4 single-shaft gas turbine for combined cycle power plant where primary frequency regulation does not conform to the requirements of East China grid, this paper provides root cause analysis in five aspects,along with a proposed solution to improve the accuracy and average adjustment performance of primary frequency regulation of the unit by resetting the function of the dead zone and the speed difference-load variation.
作者 董溢华 杨军
出处 《东方电气评论》 2018年第1期39-43,54,共6页 Dongfang Electric Review
关键词 M701F4燃机 燃气-蒸汽联合循环机组 -次调频 M701F4 gas turbine gas-steam combined cycle primary frequency regulation