期刊文献+

双源CT双能量技术在痛风诊断中的临床应用价值 被引量:3

The clinical value of dual source CT dual energy technique in the diagnosis of gout
下载PDF
导出
摘要 目的:探讨双源CT双能量技术在痛风诊断中的临床应用价值。方法:对疑似痛风患者实施DECT检查,分析DECT诊断痛风患者的临床价值、平均尿酸结晶盐体积与患者血尿酸水平的关系。结果:30例疑似患者,经临床确诊痛风患者20例,非痛风患者10例;患者血尿酸水平与踝关节、膝关节、腕关节尿酸盐结晶体积均呈显著正相关关系(P<0.05);DECT诊断痛风灵敏度95.00%,特异度90.00%,漏诊率5.00%,误诊率10.00%。结论:DECT双能量技术在诊断痛风患者尿酸结晶盐中具有较高的灵敏度和特异度,能较好地检出痛风患者的尿酸结晶盐。 Objective:To explore the clinical value of dual source CT dual energy technique in the diagnosis of gout.Methods:Patients with suspected gout were given DECT examination.We analyzed the clinical value of DECT in the diagnosis of gout,relationship between the average volume of uric acid crystalline salt and the level of blood uric acid in patients.Results:Of 30 suspected patients,20 cases were diagnosed as gout,and 10 cases were non gout.The blood uric acid level showed significant positive correlation with the urate crystalline volume of ankle joint,knee joint and wrist joint(P〈0.05).The sensitivity of DECT in the diagnosis of gout was 95%;the specificity was 90%;the rate of missed diagnosis was 5%;the rate of misdiagnosis was 10%.Conclusion:DECT dual energy technique had high sensitivity and specificity in the diagnosis of uric acid crystalline salt in gout patients.It can be used to detect the crystalline salt of uric acid in gout patients.
作者 王晗
出处 《中国社区医师》 2018年第7期142-143,共2页 Chinese Community Doctors
基金 吉林市科技计划项目(编号:201537037)~~
关键词 双源CT 双能量技术 痛风 尿酸结晶盐 Dual source CT Dual energy technique Gout Uric acid crystal salt
  • 相关文献

参考文献2

二级参考文献25

  • 1Grainger R, Taylor WJ, Dalbeth N, et al. Progress in measurement instrument s for acute and chronic gout studies IJ. J Rheumatol, 2009, 36(10): 2346-55.
  • 2Gruber M, Bodner G, Rath E, et al. Dual-energy computed tomography compared with ultrasound in the diagnosis of gout[J]. Rheumatology (Oxford), 2014, 53(1): 173-9.
  • 3Nicolaou S, Yong-Hing CJ, Galea-Soler S, et al. Dual-Energy CT as a potential new diagnostic Tool in the management of gout in the acute setting[J]. American Journal of Roentgenology, 2010, 194(4): 1072-8.
  • 4Sun Y, Ma L, Zhou Y, et al. Features of urate deposition in patients with gouty arthritis of the foot using dual-energy computed tomography[Z], 2013: 15.
  • 5Manger B, Lell M, Wacker J, et al. Detection of periarticular urate deposits with dual energy CT in patients with acute gouty arthritis IJ]. Ann Rheum Dis, 2012, 71(3): 470-U186.
  • 6Thomas C, Krauss B, Ketelsen D, et al. Differentiation of urinary calculi with dual energy CT: effect of spectral shaping by high energy Tin filtration[J]. Invest Radiol, 2010, 45(7): 393-8.
  • 7Dalbeth N, Aati O, Gao A, et al. Assessment of tophus size:a comparison between physical measurement methods and dualenergy computed tomography scanning [J]. J Clin Rheumatol, 2012, 18(1): 23-7.
  • 8Baeani AK, Mccollough CH, Glazebrook KN, et al. Dual energy computed tomography for quantification of tissue urate deposits in tophaceous gout: help from modem physics in the management of an ancient disease[J]. Rheumatol Int, 2012, 32(1): 235-9.
  • 9Karaaltmcaba M, Akta A. Dual-energy CT revisited with multi- detector CT: review of principles and clinical applications[J]. Diagn Interv Radiol, 2011, 17(3): 181-94.
  • 10Choi HK, A1-Arfaj AM, Effekhari A, et al. Dual energy computed tomography in tophaceous gout[J]. Ann Rheum Dis, 2009, 68(10): 1609-12.

共引文献33

同被引文献43

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部