期刊文献+

基于物理模型的多普勒信号模拟方法 被引量:3

Doppler Signal Simulation Method Based on Physical Model
原文传递
导出
摘要 提出了一种基于物理模型的超声多普勒信号模拟方法,它可以适用于分层、脉动、非均匀的血流情况.这种方法直接以血流情况、仪器参数等作为输入,产生同时反映正反向血流信息的解析多普勒信号.实验分析表明,用这个方法生成的信号能够较好地模拟实际多普勒信号的各种特性。 A computer method based on physical models for generating Doppler ultrasound signals from laminar, pulsatile, nonuniform flow is presented. The Doppler in phase and quadrature signals can be simulated when the flow characteristics and the instrument parameters are given as inputs. Experiments results show that the model can generate signals with characteristics similar to those of the real Doppler signals. Thus this method is effective.
出处 《复旦学报(自然科学版)》 CAS CSCD 北大核心 1999年第3期343-347,共5页 Journal of Fudan University:Natural Science
基金 教育部优秀青年教师基金 上海市青年科技启明星计划
  • 相关文献

参考文献2

  • 1汪源源,复旦学报,1998年,37卷,1期,88页
  • 2汪源源,复旦学报,1992年,31卷,4期,461页

同被引文献28

  • 1RICHARDSON P, JOHN S. Design of a continuous wave Doppler ultrasonic flowmeter for perivascular bibliography application[J]. Med Biol Eng Comput, 1987,25 : 661-662.
  • 2UEMATSU S. Determination of volume of arterial blood flow buy an ultrasonic device [J ]. J Clin Ultrasound,1981, 9 : 209-212.
  • 3GILL R W. Measurement of blood flow by ultrasound:Accuracy and sources of error[J]. Ultrasound in med &Biol, 1985, 11:625-627.
  • 4SMITH C K, HUSSAIN R, DUERINCKX A, et al. Assurance of consistent peak-velocity measurements with a variety of duplex Doppler instruments [ J ]. Radiology,1990, 17 : 265-268.
  • 5EVANS D H, MCDICKEN W N, SKIDMORE R, et al.Doppler ultrasound [ M]. Chickester: John Wiley &Sons, 1989.
  • 6GUO Z, DURAND L G, ALLARD L, et al. Cardiac Doppler blood flow signal anylysis, Part Ⅱ : The timefrequency distribution by using autoregressive modeling[J]. Med Biol Eng Comput, 1993, 31(3):242-248.
  • 7BJORN A J. Instataneous frequency, mean frequency,and variance of mean frequency estimators for ultrasonic blcxxt velocity Doppler signals[J]. IEEE Trans Brae,1981, 27(11) :365-370.
  • 8RICHARDSON P, JOHN S. Design of a continuous wave Doppler ultrasonic flowmeter for perivascular bibliography application[J]. Med Biol Eng Comput, 1987,25: 661-662.?A
  • 9UEMATSU S. Determination of volume of arterial blood flow buy an ultrasonic device [J ]. J Clin Ultrasound,1981, 9:209-212.?A
  • 10GILL R W. Measurement of blood flow by ultrasound:Accuracy and sources of error[J]. Ultrasound in med &Biol, 1985, 11:625-627.?A

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部