摘要
目的建立三藤胶囊中雷公藤酯甲含量的测定方法。方法采用HPLC法,色谱柱为Phenomenex Hyper Clore BDSC18分析柱,检测波长为210 nm,柱温为30℃,以水-乙腈为流动相,1.0 m L·min^(-1)的流速,梯度冼脱,测定三藤胶囊中雷公藤酯甲的含量。结果雷公藤酯甲在0.68~6.8μg内线性关系良好,r=0.999 9(n=5),平均回收率为98.17%,RSD=1.31%(n=9),检测限为每粒胶囊含雷公藤酯甲不低于0.046 mg。结论该方法简便准确,灵敏度高,重复性好,可以作为三藤胶囊的质量控制方法。
AIM To establish an HPLC method for the determination of Wilforlide A in Santeng capsule. METHODS The HPLC method was used with Phenomenex Hyper Clore BDS-C18 column ,with detection wavelength of 210 nm and water-acetonitrile as the mobile phase. The flow rate was 1.0 mL - min^-1. The column temperature was kept at 30℃. RESULTS Wilforlide A presented a linear range in 0.68 - 6.8 μg ,with correlation coefficient (r) as 0. 999 9. The average recoveries were 98.17% (RSD = 1.31% ) (n =9). The limit of detection was 0. 046 mg. CONCLUSION This method is simple, accurate and sensitive, and can be used for the quality control of the preparation.
作者
梁健
沈熊
吕迁洲
胡亚男
杨春欣
LIANG Jian;SHEN Xiong;LYU Qianzhou;HU Yanan;YANG Chunxin(Department of Pharmacy, Zhongshan Hospital, Fudan University, Shanghai 200032, Chin)
出处
《中国临床药学杂志》
CAS
2018年第1期40-42,共3页
Chinese Journal of Clinical Pharmacy
基金
上海市科委中药科技支撑项目(编号13401900503)