摘要
文章以某住宅楼房屋内墙体渗漏泛碱的检测鉴定为例,根据现场墙体渗漏情况检查、卫生间蓄水试验、卫生间及客厅地面砖层检查项目,并采用红外热像仪、现场对比观察等检测手段进行检测,得出卫生间在门槛石处的防水构造不合理,不能形成有效的防水构造措施,是导致卫生间附近墙体渗漏泛碱的主要原因,并针对墙体渗漏泛碱的原因,提出了相应的处理措施。
Based on a residential building the indoor wall leakage and crystalline bloom as an example,according to the wall leakage inspection, the toilet water test and check toilet sitting room ground brick layer,and using the infrared thermal imager, the scene contrast observation testing means testing, such as draw a toilet in the threshold stone waterproof structure is unreasonable, cannot form effective waterproof construction measures, this is a major cause of lead to toilet near wall leakage and crystalline bloom, and in view of the causes of leakage whiskering corresponding treatment measures are put forward.
出处
《江苏建筑》
2017年第B12期43-45,共3页
Jiangsu Construction
关键词
室内墙体
渗漏泛碱原因
检测鉴定
处理措施
indoor wall
causes of the leakage and crystalline bloom
test appraisal
treatment measures