期刊文献+

加热器端差对电厂经济性的影响

Effect of End Difference of Heater on Economy of Power Plant
下载PDF
导出
摘要 以某台300 MW机组为例,分析了锅炉的原始参数,并经计算得出热经济性指标,8台加热器上端差每降低2℃,电厂总效率提升2个百分点,下端差每降低2℃,效率下降1个百分点。在运行中应该适当地调整端差,从而提高电厂的经济性。 Taking a 300 MW unit as an example, the original parameters of the boiler were analyzed, and the thermal economic index was calculated through calculation. The difference of the upper end of 8 heaters was decreased by 2 degrees, the total efficiency of the power plant was increased by 2 percentage points, and the difference of the lower end was reduced by 2 degrees, and the efficiency decreased by 1 percentage points. Therefore, the end difference should be properly adjusted in operation so as to improve the economy of the power plant.
作者 王匡 张勇
机构地区 陕西科技大学
出处 《现代工业经济和信息化》 2017年第24期95-96,共2页 Modern Industrial Economy and Informationization
关键词 加热器 端差 电厂效率 heater end difference efficiency of power plant
  • 相关文献

参考文献2

二级参考文献1

  • 1陈学俊,陈听宽主编.锅炉原理(第二版)[M].机械工业出版社,1991.10.

共引文献23