期刊文献+

Intravitreal dexamethasone implants for diabetic macular edema 被引量:9

Intravitreal dexamethasone implants for diabetic macular edema
下载PDF
导出
摘要 AIM: To evaluate the safety and efficacy of a dexamethasone(DEX) intravitreal implant for diabetic macular edema(DME).METHODS: Totally 113 eyes of 84 patients were divided in three subgroups: naive patients(n=11), pseudophakic patients(n=72) and phakic patients(n=30). Inclusive criterion comprised adult diabetic patients with central fovea thickening and impaired visual acuity resulting from DME for whom previous standard treatments showed no improvement in both central macular thickness(CMT) and best corrected visual acuity(BCVA) after at least 3 mo of treatment. Outcome data were obtained from patient visits at baseline and at months 1, 3, 5, 9 and 12 after the first DEX implant injection. At each of these visits, patients underwent measurement of BCVA, a complete eye examination and measurement of CMT and macular volume(MV) carried out with optical coherence tomography(OCT) images. RESULTS: Seventy-three eyes(64.5%) received a single implant, 30(26.5%) received two implants and 10(9%) received three implants. At baseline, average in BCVA, CMT and MV were 43.5±20.8, 462.8±145 and 12.6±2.5 respectively. These values improved significantly at 1 mo(BCVA: 47.2±19.5, CMT: 339.6±120, MV: 11.11±1.4) and 3 mo(BCVA: 53.2±18.1, CMT: 353.8±141, MV: 11.3±1.3)(P≤0.05). At 5 mo(BCVA: 50.9±19.8, CMT: 425±150, MV: 12.27±2.3), 9 mo(BCVA: 48.4±17.6, CMT: 445.5±170, MV: 12.5±2.3) and 12 mo(BCVA: 47.7±18.8, CMT: 413.2±149, MV: 12.03±2.5), improvements in the three parameters were no longer statistically significant and decreased progressively but did not reach baseline values. There were no clinical differences between subgroups. Ocular complications were minimal.CONCLUSION: Patients with DEX implants show maximum efficacy at 3 mo which then declined progressively, but is still better than baseline values at the end of follow-up. AIM: To evaluate the safety and efficacy of a dexamethasone(DEX) intravitreal implant for diabetic macular edema(DME).METHODS: Totally 113 eyes of 84 patients were divided in three subgroups: naive patients(n=11), pseudophakic patients(n=72) and phakic patients(n=30). Inclusive criterion comprised adult diabetic patients with central fovea thickening and impaired visual acuity resulting from DME for whom previous standard treatments showed no improvement in both central macular thickness(CMT) and best corrected visual acuity(BCVA) after at least 3 mo of treatment. Outcome data were obtained from patient visits at baseline and at months 1, 3, 5, 9 and 12 after the first DEX implant injection. At each of these visits, patients underwent measurement of BCVA, a complete eye examination and measurement of CMT and macular volume(MV) carried out with optical coherence tomography(OCT) images. RESULTS: Seventy-three eyes(64.5%) received a single implant, 30(26.5%) received two implants and 10(9%) received three implants. At baseline, average in BCVA, CMT and MV were 43.5±20.8, 462.8±145 and 12.6±2.5 respectively. These values improved significantly at 1 mo(BCVA: 47.2±19.5, CMT: 339.6±120, MV: 11.11±1.4) and 3 mo(BCVA: 53.2±18.1, CMT: 353.8±141, MV: 11.3±1.3)(P≤0.05). At 5 mo(BCVA: 50.9±19.8, CMT: 425±150, MV: 12.27±2.3), 9 mo(BCVA: 48.4±17.6, CMT: 445.5±170, MV: 12.5±2.3) and 12 mo(BCVA: 47.7±18.8, CMT: 413.2±149, MV: 12.03±2.5), improvements in the three parameters were no longer statistically significant and decreased progressively but did not reach baseline values. There were no clinical differences between subgroups. Ocular complications were minimal.CONCLUSION: Patients with DEX implants show maximum efficacy at 3 mo which then declined progressively, but is still better than baseline values at the end of follow-up.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期77-82,共6页 国际眼科杂志(英文版)
基金 Supported by the Spanish Drug Regulatory Agency(No.APR-DEX-2014-01)
关键词 Ozurdex diabetic macular edema dexamethasone retina diabetes Ozurdex diabetic macular edema dexamethasone retina diabetes
  • 相关文献

同被引文献28

引证文献9

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部