随着国家档案局DA/T 45—2009档案馆高压细水雾灭火系统技术规范的颁布实施,全国有大量的新建改建档案库房采用了高压细水雾灭火系统。通过对沁水县档案馆档案库房细水雾灭火系统设计,对GB 50898—2013细水雾灭火系统技术规范中部分条文提出不同见解,并进行技术经济分析,以期对细水雾灭火系统的设计提供借鉴。
Combining with the DA/T 45-2009 Technical Specification for High Pressure Water Mist System in Archives, massive newly-built andrebuilt archives repositories begin to adopt the technical code for water mist fire extinguishing system. In order to provide reference to the designof the system, we have designed the related system for the storehouse of Qinshui County Archives, expressed some different opinions on parts ofthe technical specification GB 50898-2013 and analyzed it technically and economically.