配电终端失效分布类型判断及失效率估算 被引量:7

Judgment on Failure Distribution Type and Estimation of Failure Rate for Distribution Terminals
下载PDF
导出
摘要 配电终端的可靠性直接影响整个配电自动化系统的稳定运行。为合理预测其失效趋势,研究了配电终端失效分布类型判断及失效率估算方法。首先根据经验分布函数,初步判断配电终端某模块的失效分布函数,并利用参数估计和拟合优度检验,确定该模块的失效分布类型;然后根据所得参数和失效分布函数求得该模块的失效率函数,进一步求和得到整个配电终端的失效率;最后拟合得到的失效率函数符合一般设备的"浴盆曲线"特征,通过案例验证了所提方法可行而有效。 The reliability of distribution terminals directly affects the stability of the whole distribution automation system. To predict its failing trend,a method for judging the failure distribution type and estimating the failure rate is proposed. Firstly,the failure distribution function of a module in the distribution terminal is judged according to an empirical distribution function,and then the failure distribution type of the module is determined through parameter estimation and goodness of fitting tests. Secondly,the failure rate function of the module is calculated using the obtained parameters and failure distribution function,and the failure rate of the whole distribution terminal can be calculated by summation. Finally,the failure rate function obtained through fitting can satisfy the"Bathtub"curve,which is also a characteristic of general equipment,and the feasibility and efficiency of the proposed method are verified through a case study.
出处 《电力系统及其自动化学报》 CSCD 北大核心 2018年第2期61-65,共5页 Proceedings of the CSU-EPSA
基金 国家电网公司总部科技资助项目(配电自动化系统精益化运维关键技术研究与开发) 广东省绿色能源技术重点实验室项目(2008A060301002)
关键词 配电终端 可靠性 失效分布类型 失效率 distribution terminal reliability failure distribution type failure rate
  • 相关文献

参考文献18

二级参考文献192

共引文献968

同被引文献115

引证文献7

二级引证文献45