浅谈受矿区塌陷影响的高压架空线路的治理

Treatment of High Voltage Overhead Line Affected by Collapse in Mining Area
下载PDF
导出
摘要 向矿区提供生产、生活所需电力的高压架空线路是矿区安全、稳定生产的重要保障,本文简要介绍了煤矿高压架空供电线路受采矿塌陷影响后造成的杆塔倾斜、变形;导线弧垂严重变化等影响线路安全运行情况的就地治理及防范措施,对今后煤矿企业架空供电线路受塌陷影响的维护、治理具有一定借鉴意义。 The high-voltage overhead line to provide the power for production and living of mine area is the important guarantee of mine safety and the stable production of the coal mine, this paper briefly introduces the high voltage overhead power lines affected by mining subsidence caused by the influences of tower inclination deformation; local governance, serious changes of conductor sag line operation and preventive measures, to maintenance and of governance the overhead power lines affected by collapse has certain reference significance in future.
作者 李平方
出处 《煤矿现代化》 2018年第3期131-132,共2页 Coal Mine Modernization
关键词 矿区塌陷 高压架空线路 就地治理 subsidence of mine area high pressure overhead line in-situ treatment