摘要
目前,在工业建筑中屋面普遍采用轻钢结构,屋面坡度一般为5%,而单坡长度越来越长,现已达到90 m。短时暴雨情况下积水会给屋面增大多少荷载,带来多大影响,是值得重视和研究的新课题。要解决此问题,首先须知道暴雨强度公式,由各等流时线断面处设计流量q_i的计算求出雨水深度,获得特定条件下的雨压。
At present,light steel structure is generally adopted in the roofs of industrial buildings.The slope of the roof is generally 5%,but the length of single slope is longer and longer,now it has reached 90 m. Under short-term rainstorm,how much load the water will bring to the roof and how much impact it brings will be a new topic worthy of attention and research. To solve this problem,we must first know the formula of rainstorm intensity,and calculate the depth of rainwater based on the design flow volume of each equal time line section,and obtain the rain pressure under certain conditions.
出处
《建筑技术开发》
2018年第5期13-14,共2页
Building Technology Development
关键词
暴雨强度
雨荷载
单宽流量
积水深度
汇流时间
rainstorm intensity
rain load
single wide flow
water accumulation depth
confluence time