摘要
介绍了LWH-106D缓蚀剂在某催化裂化装置中的应用,分析了湿硫化氢对催化裂化设备的腐蚀机理及防护。实际应用结果表明,LWH-106D缓蚀剂对催化分馏塔顶的冷换设备和管线防腐效果良好;水样中的铁离子浓度由2.41 mg/L下降到0.29 mg/L,pH平均值为9.19,降低了设备的维修费用,保证装置长周期运行。
The application of LWH-106 D corrosion inhibitor in a catalytic cracking unit is introduced.The corrosion mechanism of hydrogen sulfide on catalytic cracking equipment are analyzed and the corresponding protection methods are discussed.The results show that the LWH-106 D corrosion inhibitor exhibits good anti-corrosion effect for the cold change equipment and pipelines at the top of the catalytic fractionation tower.The iron ion concentration in water samples decreases from 2. 41 mg·L^(-1) to 0. 29 mg·L^(-1),and the average pH value is 9. 19,which can lower the maintenance cost of the equipment and ensure the long cycle run of the facility.
作者
王莲静
WANG Lian-fing(The Oil Refinery, PetroChina Daqing Petrochemical Company, Daqing 163711, Chin)
出处
《现代化工》
CAS
CSCD
北大核心
2018年第3期196-198,共3页
Modern Chemical Industry
关键词
缓蚀剂
催化裂化
腐蚀
铁离子
corrosion inhibitor
catalytic cracking
corrosion
iron ion