摘要
基于现行规范中的有关条款及工程实际,总结并指出高大空间在进行防烟分区划分时可能出现的问题。结合工程案例,分析了对于高度大于6 m的高大空间采用逻辑防烟分区时的排烟系统设计方法,为大空间建筑排烟系统合理设计提供参考。
The problems possibly occurred in the smoke compartmenting for large space were summarized and pointed out based on the relevant provisions in current code and engineering practice. Combined with engineering cases, the design method of Logical Smoke ControI Partition for smoke exaction system in large space with height greater than 6m was analyzed to provide reference for reasonable smoke management system design in large space building.
出处
《消防技术与产品信息》
2018年第3期18-20,共3页
Fire Technique and Products Information
关键词
高大空间建筑
排烟系统
防烟分区
逻辑防烟分区
large space building
smoke management system
smoke compartment
Logical Smoke Control Partition