期刊文献+

氢氧化铁共沉淀-电感耦合等离子发射光谱法测卤水中的痕量铜铅锌 被引量:1

Determination of trace copper,lead and zinc in brine by inductively coupled plasma-Atomic emission spectrometry after co-precipitation with iron hydroxide
下载PDF
导出
摘要 用Fe(OH)3共沉淀分离卤水中的铜铅锌,用1+1的王水溶解沉淀定容,电感耦合等离子发射光谱法测定。检出限为LD(Cu Zn)=0.041mg·L^(-1),LD(Pb)=0.11mg·L^(-1),加标回收率为95.25%~101.9%,精密度(n=12)为1.15%。结果表明:本方法快速准确,可以准确测定卤水中铜铅锌。 Separation of iron hydroxide co-precipitation copper,lead and zinc in brine, with 1 + 1 the capacity, dissolution precipitation inductively coupled plasma emission spectrometry.The detection limit of the copper and zinc were0.041mg·L-1, The detection limit of the lead were 0.11mg·L-1, the receveries differ from 95.25% to 101.9 %,the precision of the method were 1.15% RSD (n=12). The result shows that this method is fast and accurate, so it can satisfy the detection by rule and line of Copper, Lead and Zinc in brine.
作者 袁红战 武丽平 李文波 张旭 YUAN Hong-zhan, WU Li-ping, LI Wen-bo,ZHANG Xu(Testing Center of Qinghai Chaidamu Comprehensive Geological and Mineral Exploration Academy, Geermu 816000, Chin)
出处 《化学工程师》 CAS 2018年第3期25-26,52,共3页 Chemical Engineer
关键词 共沉淀 卤水 电感耦合等离子发射光谱法 co-precipitation inductively coupled plasma-atomic emission spectrometry (ICP-AES) brine copper lead zinc