摘要 工业铂热电阻测量的可靠性关系着产品的生产质量,本文基于工业铂热电阻的测温原理和检定标准,分析了工业铂热电阻检定的不确定度来源,并计算了各种不确定度分量对测量检定结果的贡献比值,能够为提高工业铂热电阻的测量精度提供可靠的理论依据,具有较好的工程实用价值。 The reliability of the industrial platinum thermal resistance measurement is related to the production quality of the product.The temperature measurement principle and calibration of standard industrial platinum resistance based on the analysis of the uncertainty of industrial platinum resistance verification of sources, various uncertain contribution ratio components on the measurement and calculation of the test results, which can provide theoretical basis for improving the measurement accuracy of industrial platinum resistance, and the scheme is more applicable in engineering.
作者 颜烺 Yan Lang(Metrology and Testing Institute ofTaizhou, Taizhou 22530)
出处 《仪器仪表标准化与计量》 2018年第1期32-34,38,共4页 Instrument Standardization & Metrology
关键词 工业铂热电阻 不确定度 检定装置 Industrial Platinum Thermal Resistance Uncertainty Verification Device
  • 相关文献

参考文献6

二级参考文献13

  • 1宋德华,宋涛.指标高 设备大 检定繁 对JJG229-1998检定规程的修改建议[J].中国计量,2006(3):24-25. 被引量:6
  • 2国家技术监督局计量司.1990国际温标宣贯手册[M].北京:中国计量出版社,1990..
  • 3国家质量技术监督局 .测量不确定度评定与表示[M].北京:中国计量出版社,..
  • 4国家质量技术监督局 .计量标准考核规范[M].北京:中国计量出版社,..
  • 5国家质萤监督检验检疫总局.二等标准水银温度计检定规程(JJG128--2003).北京:中国计量出版社,2003
  • 6国家质萤技术监督局.测萤不确定度评定与表示技术规范(JJF1059--1999).北京:中国计量出版社,1999
  • 7国家质量监督检验检疫总局. JJF 1030 -2010恒温槽技术性能测试规范[S].北京:中国计量出版社,2010.
  • 8国家质量监督检验检疫总局.JJG160-2007标准铂电阻温度计[S].北京:中国计量出版社,2007.
  • 9JJF 1059-1999.测量不确定度评定与表示[S]..1999
  • 10宋年兰.关于《对JJG229-1998检定规程的修改建议》的几点看法[J].中国计量,2008(2):115-116. 被引量:9

共引文献34

同被引文献5

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部