为更加深入落实新安全生产法,确保站内安全生产,对西气东输集气站排污池存在的回火安全隐患进行了分析。依据国家相关标准设计计算,通过实验验证介质在不同工况下的安全性,并在采集了凝液回收区各类生产数据后,最终设计了水封装置。
In order to further implement the new safety production method and ensure the safe production in the station, the potential safety risks of tempering in the sewage collection basin of the West-East Gas Pipeline Station were analyzed.According to the design and calculation of relevant national standards, The safety of the situation, and collected my station condensate recovery zone of various types of production data, the final design of the water seal device.
作者
茅天适
何林翰
江铭峰
江一民
Mao Tian-shi, He Lin-han, Jiang Ming-feng, Jiang Yi-min
出处
《化工设计通讯》
CAS
2018年第2期109-109,共1页
Chemical Engineering Design Communications
关键词
排污池
防止回火
水封装置
drainage tank
prevent tempering
water seal device