改良型A^2/O工艺在污水处理厂的应用 被引量:3

Application of Improved A^2/O Process in Wastewater Treatment Plant
下载PDF
导出
摘要 本研究考察了以改良型厌氧/缺氧/好氧(A^2/O)工艺为工程主体的污水处理厂对市政污水的处理效果。污水处理厂出水水质均达到《城镇污水处理厂污染物排放标准》(GB18918-2002)中一级B排放标准,其中SS、CODCr、NH3-N、TN和TP去除率分别达到98.2%、93.1%、99.5%、75.5%和97.3%,且各指标去除率全年波动不超过6.9%。结果表明,改良A^2/O工艺对市政污水中有机物、氮和磷的去除效果不但显著且非常稳定。 The treatment efficiency of wastewater treatment plants with improved anaerobic/anoxic/aerobic (A2/O) process as the main part for municipal wastewater was investigated in this study. The results showed that the effluent quality could meet the Grade I -B discharge standard required by the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB18918-2002), and the removal efficiency of SS, CODcr, NH3-N, TN and TP were 98.2 %, 93.1%, 99.5 %, 93.1% and 99.5 %, respectively. It was also to be found that the fluctuation of removal efficiency for each indicators was no more than 6.9 %. The above research showed that the removal efficiency of organic, nitrogen and phosphorus in municipal wastewater treated by improved A2/O was not only significant but also very stable.
作者 方阳 林伟刚 蔡少卿 陈新乐 方燕芳 徐雨晴 刘莹 Fang Yang, Lin Weigang, Cai Shaoqing, Chela Xinle, Fang Yanfang, Xu Yuqing, Liu Ying,.(1. Taizhou Huangyan District Municipal Public Works Quality Supervision Station, Taizhou 318020, 2. Ninghai Water Supply Co., Ltd, Ningbo, 315600,3.Environmental Engineering Co., Ltd., Hangzhou 310012,4. Haining Environmental Protection Monitoring Station, Jiaxing 314400, 5. Hangzhou Yi Tai Environmental Protection Co., Ltd., Hangzhou 311100, 6. Hangzhou Normal University College of Life and Environmental science, Hangzhou 310018, Chin)
出处 《广东化工》 CAS 2018年第5期202-203,共2页 Guangdong Chemical Industry
基金 杭州师范大学本科生创新能力提升工程项目(cx2017104 cx2017116)
关键词 改良型A2/O 污水处理 脱氮除磷 improvedA2/O waste water treatment nitrogen and phosphorus removal
  • 相关文献

参考文献10

二级参考文献72

共引文献105

同被引文献7

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部