摘要 采用MC法,引入MIRD体模模型,通过改变放射源^(60)Co与人体的垂直距离,模拟计算肺部肿瘤组织剂量随距离因素的变化关系曲线。结果表明:理论推导模型计算的吸收剂量D随距离的增加呈现出下降的趋势,并且距离r的幂次方取值范围大约为1.9~2.1。模拟结果与理论计算误差在10%以内,说明该理论计算模型是一种有效可行、简单方便的剂量估算方法。 A simulation of dose of ^60Co adsorbed by lung tumor concerning the distance in between was performed by using Mont Carlo method and introducing MIRD body phantasms, meanwhile the curve of adsorbed dose against distance was conducted. The results showed that theoretical calculation in dose adsorption (D) drops with increasing distance (r), and the power of distance (r) should be located between 1.9 and 2. 1. The error between simulation and theoretical calculation is less than 10%, which indicates the theoretical calculation in this study is an effective and easy way to estimate the adsorbed dose.
作者 赵永生 向学城 王东航 颜瑜成 ZHAO Yong-sheng;XIANG Xue-cheng;WANG Dong-hang;YAN Yu-cheng(The Engineering & Technical College of Chengdu University of Technology, Leshan, Sichuan 614000, China;Southwestern Institute of Physics, Chengdu 610041, China)
出处 《核电子学与探测技术》 北大核心 2017年第7期716-719,共4页 Nuclear Electronics & Detection Technology
基金 乐山市重点科技计划(A322013006)资助
关键词 MC模拟 MIRD体模 吸收剂量 剂量估算 MCNP simulation MIRD body model adsorbed dose dose assessment
  • 相关文献

参考文献2

二级参考文献22

  • 1张斌全,马吉增,程建平,刘立业,毛永.蒙特卡罗方法计算用于低能光子测量的高纯锗探测器的效率[J].核电子学与探测技术,2005,25(3):274-277. 被引量:26
  • 2张斌全,马吉增,程建平,杨端节,刘立业.使用人体躯干物理模型的CT模型和蒙特卡罗方法校准肺部计数器[J].辐射防护,2006,26(2):85-92. 被引量:6
  • 3Krsmer G H, Hauck B M, Allen S A. Comparison of the LLNL And JAERI Torso Phantoms Using Ge Detectors and Phoswich Detectors. Health Physics, 1998.74(5 ) : 594.
  • 4Kramer G H, Hauck B M. Intercomparison of JAERI Torso Phantom hmg Sets. Rad. Prot. Dosim., 2000.88 (4) :311.
  • 5IAEA. Intercomparison of Radiological Measurements for Monitoring Purposes: Direct Measurement of Radionuclides in Simulated Organs Protocol. IAEA, 2001-2002
  • 6ICRU. Tissue Substitutes in Radiation Dosimetry and Measurement. ICRU Report 44. Bethesda, 1989.
  • 7Hunt J G, Bertelli L. Calibration of in Vivo Measurement Systems and Evaluation of Lung Measurement Unceitainties Using a Voxel Phantom. Paid. Prot.Dosim., 1998.76(3) : 179.
  • 8Mallett M W, Hickman D P, Knuchen D. A, et al.Development of a Method for Calibrating in Vivo Measurement Systems Using Magnetic Resonance Imaging and Monte Carlo Computations. Health Phys., 1995.68(6) :773.
  • 9http://physics. nist. gov/PhysRefData/XrayMassCoef/cover, html.
  • 10ICRP.Report of the task group on Reference Man,1975.