期刊文献+

放射性废液取样手套箱厚度最优化的蒙特卡罗计算

Radioactive Waste Sampling Glove Box Thickness Optimization by Monte Carlo Calculation
下载PDF
导出
摘要 放射性废液取样手套箱可降低蒸残液对工作人员的辐射危害作用,为使综合照射所致个人总有效剂量不超过相应剂量限值的同时达到最优化水平,确定手套箱屏蔽厚度。本文采用MCNP程序对不锈钢手套箱厚度进行屏蔽计算,应用代价利益分析法,得出放射性废液取样手套箱最优化屏蔽层厚度。 Radioactive waste sampling glove box can reduce the damaging effects of radiation distilled residue of staff,in order to meet the requirements of radiation protection and optimization,to determine the thickness of the shield glove box,making the integrated irradiation due to personal total effective dose not to exceed the dose limit at the same value and achieve optimal levels is very important. In this paper,MCNP procedures for stainless steel glove box shielding calculations are applied to the cost-benefit analysis of radioactive waste derived optimal sampling glove box shielding layer thickness.
作者 刘艳芳 张江云 胡一非 张志鹏 祝美英 雷小兵 窦义同 苟家元 LIU Yan-fang,ZHANG Jiang-yun, ZHU Mei-ying, LEI Xiao-bing, HU Yi-fei, ZHANG Zhi-peng, DOU Yi-tong, GOU Jia-yuan(Nuclear Power Institute of China, Chengdu 610005, Chin)
出处 《核电子学与探测技术》 北大核心 2017年第8期788-791,共4页 Nuclear Electronics & Detection Technology
关键词 手套箱 最优化 屏蔽厚度 MCNP glove box cost-benefit analysis Shield thickness MCNP
  • 相关文献

参考文献1

二级参考文献4

  • 1国际放射防护委员会2007年建议书[R].第1版.北京:原子能出版社.2008.
  • 2IAEA. Optimization of radiation protection in the control of occupational exposure[R]. IAEA. Safety Reports Series No. 21. 2002.
  • 32007年世界卫生报告[R].北京:人民卫生出版社.2007.
  • 4李春海.辐射防护α值的估算[J].中国辐射卫生,2000,9(4):205-207. 被引量:3