期刊文献+

HL-2M装置中性束离子源束光学红外成像实验研究 被引量:1

Beam optics characteristics based on infrared thermography for HL-2M NBI ion source
下载PDF
导出
摘要 为了研究HL-2M装置中性束注入(NBI)加热用的80k V/45A/5s热阴极离子源束光学特性,采用红外电荷耦合元件(CCD)成像技术,测量离子源引出粒子束轰击量热靶板产生的温度分布,得到束功率密度空间分布区间特征参数1/e半宽度。在NBI热阴极离子源调试平台上,扫描离子源的放电和引出参数,利用CCD红外热像仪获得了对应参数下量热靶上的束功率密度分布。实验结果表明,HL-2M装置NBI加热系统80k V/45A离子源可用的导流系数范围为0.7~1.5?P。同样导流系数下,梯度电极与等离子体电极的分压比较高时,引出束流的半宽度较小。 In order to study the optic characteristics of 80kV/40A/5s hot-cathode ion source of neutral beam injector (NBI) on HL-2M tokamak, Charge-coupled Device (CCD) infrared therrnography technology was used to measure the temperature distribution caused by the beam bombardment on the calorimetric target and the feature parameter (1/e half width) of beam power distribution was obtained. On the NBI hot-cathode ion source platform, the discharge and extraction parameters of the ion source were scanned, and beam power distributions on the calorimetric target were obtained. The experimental results show that the available perveance range of 80kV/45A ion source on HL-2M NBI system was 0.7-1.5μP. In the same perveance, when the voltage ratio of the gradient electrode to the plasma electrode is higher, the half width of the extraction beam power distribution is smaller.
作者 周博文 邹桂清 曹建勇 魏会领 刘鹤 周红霞 何峰 杨宪福 罗怀宇 潘春花 ZHOU Bo-wen1, ZOU Gui-qing2, CAO Jian-yong2, WEI Hui-ling2, LIU He2, ZHOU Hong-xia2, HE Feng2, YANG Xian-fu2, Chun-hua2 PAN Chun-hua2(1. Southwest Jiaotong University, Superconductivity and New Energy R&D Center, Chengdu 610031; 2. Southwestern Institute of Physics, Chengdu 61004)
出处 《核聚变与等离子体物理》 CAS CSCD 北大核心 2018年第1期42-47,共6页 Nuclear Fusion and Plasma Physics
基金 国家磁约束核聚变能发展研究专项(2011GB103000) 国家自然科学基金(11405048)
关键词 HL-2M装置 中性束注入离子源 导流系数 红外热像仪 HL-2M tokamak Neutral beam injector ion source Perveance Infrared thermography
  • 相关文献

参考文献2

二级参考文献11

共引文献8

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部