期刊文献+

联合检测高荧光细胞和CEA对恶性积液的诊断价值 被引量:3

Diagnostic value of combined detection of high-fluorescent cell and CEA for malignant hydrothorax or ascites
下载PDF
导出
摘要 目的:探讨胸腹水中HF-BF%、HF-BF#和CEA的联合检测在良恶性胸腹腔积液鉴别诊断中的价值.方法:收集2014年11月至2016年12月胸腹水标本110例,其中恶性肿瘤53例(恶性组),非恶性肿瘤57例(良性组),进行胸腹水高荧光细胞绝对值(HF-BF#)及比率(HF-BF%)和CEA的测定,并对相关数据进行统计分析.结果:恶性组HF-BF#、HF-BF%和CEA水平均明显高于良性组,差异有统计学意义(P〈0.01);相关性分析显示,胸腹水中HF-BF#和HF-BF%与CEA均未发现明显的关联性;经ROC曲线分析得到HF-BF#、HF-BF%、CEA的单独检测的ROC曲线下面积分别为0.820、0.737、0.933;而两项联合检测(HF-BF#+CEA,HF-BF%+CEA)的ROC曲线下面积均明显高于单独检测.结论:对于良恶性胸腹腔积液的鉴别,高荧光细胞和CEA的联合检测可以提供肿瘤细胞的筛选信息,具有较好的临床应用价值. Objective: To investigate the value of combined detection of HF-BF%,HF-BF# and CEA in the differential diagnosis of benign and malignant hydrothorax or ascites. Methods: The hydrothorax or ascites of 110 patients admitted to the First People's Hospital of Zhaoqing from December to January 2014-2016 wascollected. The cancer patients (malignant group)in 53 cases, 57 cases of the non-cancer patients (benign group). The CEA,highly fluorescent cells absolute value (HF-BF#)and percentage (HF-BP%)of ascites and pleura/effusions were detected, and related datawere conducted for statistical analysis. Results: The levels ofHF-BF#, HF-Blm/0 and CEA of the malignant group were significantly higher than those of the benign group (P〈0.01). According to the Spearman correlation analysis, there is not obvious relevance between the HF-BF#, HF-BF % and CEA in hydrothorax or ascites. According to 1KOC curve analysis, the of single indicator detection ofHF-BF#, HF-Bt% and CEA area under the curve(AUC)was 0.820, 0.737 and 0.933, The AUC of the two combined detection indicators were significantly higher than those of single indicator detection. Conclusion: The combined detection of high- fluorescent cell and CEA can provide the presence of abnormal cells and has significant clinical attlication value.
作者 莫燕芳 刘健 梅敏 梁莉红 李海珠 Mo Yanfang, Liu Jian, Liang Lihong, et al(The clinical department, the first people hospital of Zhaoqing, Guangdong Zhaoqing 52606)
出处 《医学检验与临床》 2017年第11期25-27,共3页 Medical Laboratory Science and Clinics
关键词 胸腹腔积液 恶性 高荧光细胞 癌胚抗原 Pleural effusion Malignant High-fluorescent cell Carcino-embryonic Antigen
  • 相关文献

参考文献5

二级参考文献42

  • 1Pastor A,Menendex R,Cremades MJ,et al.Diagnostic value of sce CEA and CYFRA 21.1 in lung cancer[J].Abayseian analysis Eur Respir J,1997,10(3):603-609.
  • 2Valdes L,San Jose E,Alvarez D,et al.Adenosine deaminase (ADA) Zsoenzyme analysis in pleural effusions:diagnostic role,and relevanc the origin of increased ADA in tuberculous pleurisy[J].Eur Respir J,1996,9(4):747-751.
  • 3Alemán C,Sanchez L,Alegre J. Differentia-ting between malignant and idiopathic pleural effu-sions:the value of diagnostic procedures[J].{H}QUARTERLY JOURNAL OF MEDICINE,2007,(06):351-359.
  • 4Kleinberg L,Holth A,Fridman E. The diag-nostic role of claudins in serous effusions[J].{H}American Journal of Clinical Pathology,2007,(06):928-937.
  • 5Lee JH,Chang JH. Diagnostic utility of serum and pleural fluid carcinoembryonic antigen,neuron-specific enolase,and cytokeratin 1 9 fragments in patients with effusions from primary lung cancer[J].{H}CHEST,2005,(04):2298-2303.
  • 6Korczynski P,Krenke R,Safianowska A. Diagnostic utility of pleural fluid and serum markers in differentiation between malignant and non-malignant pleural effusions[J].{H}European Journal of medical Reseasarch,2009,(Suppl 4):128-133.
  • 7Perné A,Hainfellner JA,Womastek I. Per-formance evaluation of the Sysmex XE-5000 hemato-logy analyzer for white blood cell analysis in cerebro-spinal fluid[J].{H}ARCHIVES OF PATHOLOGY AND LABORATORY MEDICINE,2012,(02):194-198.
  • 8De Jonge R,Brouwer R,de Graaf MT. Evalu-ation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids[J].{H}Clinical Chemistry and Laboratory Medicine,2010,(05):665-675.
  • 9Paris A,Nhan T,Cornet E. Performance evaluation of the body fluid mode on the platform Sys-mex XE-5000 series automated hematology analyzer[J].Int J Lab Hematol,2010,(05):539-547.
  • 10De Jonge R,Brouwer R,Smit M. Automated counting of white blood cells in synovial fluid[J].{H}Rheumatology(Oxford),2004,(02):170-173.

共引文献32

同被引文献53

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部