摘要 为了提高通信机房设备运行率和管理水平,实现设备集中维护,提高通信调度人员的工作效率,包头供电局依据包头电网的实际情况建设了功能全面的通信机房动力环境监控系统。该系统可对包头供电局管辖的变电站通信机房的电源、蓄电池、机房环境进行实时监控,使运行管理部门能及时准确了解电源设备的运行状态、各类故障告警、机房环境等信息,并具有较全面的分析、处理和统计功能,实现了对通信机房的科学管理,为通信机房的安全、稳定运行提供了有力保障。 In order to improve the equipment operation rate and management level of the communication room and realize the centralized maintenance of the equipment and improve the working efficiency of the communication dispatcher, Baotou Power Supply Bureau has established a comprehensive functional communication room monitoring system based on the actual situation of Baotou power grid. The power supply, battery, room environment of the substation communication room are real-time monitored by the system, so that the operation and management department can timely and accurately know the power equipment operating status parameters, all kinds of environment. The system with comprehensive analysis, processing can achieve the scientific management of the communication room fault alarm and room and statistical function, and ensure the safe and stable operation of the communication room.
作者 张巨慧 杨凯峰 ZHANG Juhui, YANG Kaifeng(Baotou Power Supply Bureau, Baotou 014030, Chin)
机构地区 包头供电局
出处 《内蒙古电力技术》 2018年第1期56-59,共4页 Inner Mongolia Electric Power
关键词 动力环境监控系统 电力通信网 通信机房 设备运行状态 故障告警 dynamic environment monitoring system power communication network communication room equipment operation status error alarm